PR 84721
Garbage characters "NaN" shows up above the File Operations section in System File Management on
OS8800.
Workaround: Ignore the garbage character, they are cosmetic.
PR 84780
On the OS8800, in WebView, Physical > Ethernet > Interface Configuration > General "Modify" window
might display a "Set operation finished successfully!" message and the changes not made to the table.
Workaround: Use the "Multiple Modify" window and select the desired slot/port to perform the changes.
PR 87494
On the OS6800, by default the BPDU Switching is disabled and the WebView page "Spanning Tree One
to One Bridge Parameters" displays an empty field. Only if a user modifies the bridge parameters and sets
the BPDU Switching to Enable or Disable the values will be displayed in the table.
Workaround: If the BPDU Switching field is empty, please treat it as disabled.